Laundry and Pump Room Container
This 10x10 container holds a stacked washer-dryer unit and storage for housekeeping as well as the access points for the plumbing and water filtration.
main line that comes in through the on-site well, and then runs to potable water sources
main line that comes in through the building’s cistern, which is pumped through a 2-stage hanging filter and UV filter, then runs to all the non potable fixtures, including toilets, irrigation for green roofs and farm, and hose bibs
sump basin collects water from all the condensation lines from HVAC units; gets pumped into the cistern and becomes part of the closed-loop wastewater treatment system.
pump room is entirely smart control - this system, coupled with the pump, should be able to provide the facility with potable water for up to 10 days in the event of a grid outage.